<LOGO>
FM Transmitter Measurement Report
Created: 2026-11-05 19-11-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 3/5, 64 dBuV SET FIRE
Pilot RDS Phase Difference
7.7 kHz 3.9 kHz 4 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 62 kHz 18452 0,6774
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,8 dBr 1,98 dBr 3,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SET FIRE" 4F04 10 (Pop M) 1 0 1 1 --:--
RT
" Jetzt auf DAB+ wechseln und FM1 rauschfrei geniessen "
AF EON
87.8, 93.7, 99.1, 99.2, 99.7, 100.8, 103.9 MHz -
FM Scope Max at: 62 kHz MIN: 11 kHz % above 76 kHz: 0,6774 Acquired: 2026.11.05 19.10.02 Total samples: 18452 Equivalent time: 0:15:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 3,0 dBr MIN: 0,8 dBr AVE: 1,98 dBr % above 12,2 dBr: 0,0 Last value: 3,0 dBr (2026.11.05 19.10.01) 18.56 18.58 19.00 19.02 19.04 19.06 19.08 19.10 -1 0 1 2 3 4 Pm [dBr]